40 research outputs found

    Preclinical SPECT imaging based on compact collimators and high resolution scintillation detectors

    Get PDF

    Design and performance of a compact and stationary microSPECT system

    Get PDF
    Purpose: Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial resolutions range from 0.58 to 0.76 mm while peak sensitivities vary from 0.06% to 0.4%. While pushing the limits of performance is of major importance, the authors believe that there is a need for smaller and less complex systems that bring along a reduced cost. While low footprint and low-cost systems can make microSPECT available to more researchers, the ease of operation and calibration and low maintenance cost are additional factors that can facilitate the use of microSPECT in molecular imaging. In this paper, the authors simulate the performance of a microSPECT imager that combines high space-bandwidth detectors and pinholes with truncated projection, resulting in a small and stationary system. Methods: A system optimization algorithm is used to determine the optimal SPECT systems, given our high resolutions detectors and a fixed field-of-view. These optimal system geometries are then used to simulate a Defrise disk phantom and a hot rod phantom. Finally, a MOBY mouse phantom, with realistic concentrations of Tc99m-tetrofosmin is simulated. Results: Results show that the authors can successfully reconstruct a Defrise disk phantom of 24 mm in diameter without any rotating system components or translation of the object. Reconstructed spatial resolution is approximately 800 mu m while the peak sensitivity is 0.23%. Finally, the simulation of the MOBY mouse phantom shows that the authors can accurately reconstruct mouse images. Conclusions: These results show that pinholes with truncated projections can be used in small magnification or minification mode to obtain a compact and stationary microSPECT system. The authors showed that they can reach state-of-the-art system performance and can successfully reconstruct images with realistic noise levels in a preclinical context. Such a system can be useful for dynamic SPECT imaging. 2013 American Association of Physicists in Medicine

    Design of a static full-ring multi-pinhole collimator for brain SPECT

    Get PDF
    In clinical practice, brain SPECT is mostly performed using a dual-head SPECT scanner with fan-beam or parallel-beam collimators rotating around the patient's head. The resolution of such a system is typically about 6-8 mm, which is rather poor to image the complex structures of the human brain. We developed a non-rotating multi-pinhole collimator for brain SPECT imaging with a resolution of 4 mm. A full-ring geometry allows for complete transaxial sampling. This enables the use of a stationary collimator. The collimator is a tungsten ring with two rows of pinholes. Each pinhole can individually be opened or closed with shutters. A sequence of shutter movements is performed to obtain an acquisition setup that simulates a rotational movement. The collimator is designed for the LaPET system (a PET detector ring made of 24 LaBr 3 detectors) and is optimized to maximize the system performance, resulting in a collimator radius of 145 mm and a pinhole diameter of 2 mm. This system has a sensitivity that is 4 times lower than a dual-head system with LEHR parallel-beam collimators. However, the resolution is 2 times better, a trade-off that is supported by Muehllehner [1]. Monte-Carlo simulated projections of a resolution phantom are successfully reconstructed and the resulting image shows that a resolution of 4 mm is indeed achieved

    A high resolution SPECT detector based on thin continuous LYSO

    No full text
    Single-photon emission computed tomography (SPECT) detectors with improved spatial resolution can be used to build multi-pinhole SPECT systems that have a higher sensitivity or a higher spatial resolution. In order to improve the spatial resolution we investigate the performance of a 2 mm thick continuous Lutetium Yttrium Orthosilicate (LYSO) scintillator and compare it to the performance of a 5 mm thick continuous NaI(Tl) scintillator. The advantages of LYSO are its high stopping power and its non-hygroscopicity. Drawbacks are the lower light output and the intrinsic radioactivity. The hypothesis of this study is that such a thin LYSO scintillator will have a small light spread and, as a consequence, will also have an improved spatial resolution when coupled to a Hamamatsu H8500 position sensitive photomultiplier tube. To optimize the spatial resolution and the useful detector area we used a mean nearest neighbor event-positioning method. Beam source measurements (99mTc, 140 keV) were done to investigate the energy resolution and the spatial resolution of both detectors. The effect of the intrinsic radioactivity of the LYSO scintillator in the energy window was quantified. The mean energy resolution is 9.3% for the NaI(Tl) scintillator and 21.3% for the LYSO scintillator. The LYSO spectrum shows an X-ray escape peak which decreases the detection efficiency with 9.1%. The spatial resolution of the LYSO detector (0.93 mm full width at half maximum (FWHM)) is superior to the spatial resolution of the NaI(Tl) detector (1.37 mm FWHM). The intrinsic radioactivity in the energy window (42% window centered at 140 keV) is low (125.6 cps, 0.024 cps mm−3). LYSO is a promising scintillator for small-animal SPECT imaging, where spatial resolution is more important than energy resolution

    The lofthole: a novel shaped pinhole geometry for optimal detector usage without multiplexing and without additional shielding

    No full text
    Multi-pinhole collimator based SPECT systems are nowadays used for pre-clinical and clinical imaging. Overlap of the different projections of the pinholes should generally be avoided. This can be done by either positioning the pinholes far from each other or by using additional shielding. The first method does not allow to use the detector area efficiently while the second method introduces additional cost, weight and design complexity. We investigate a new pinhole geometry, the lofthole, that has a circular aperture but whose entrance and/or exit opening is shaped by the desired irradiated detector area. The lofthole is designed using a ray-tracer and can be manufactured with traditional manufacturing techniques. A lofthole and two regular pinholes have been made in two tungsten-alloy plates. Production of these plates indicates that the manufacturing cost of a pinhole is roughly similar to the manufacturing cost of a lofthole. Measurements on the lofthole and pinhole plates show the rectangular projection of the lofthole versus the circular projection of the pinhole. Penetration measurements indicate that the lofthole has less penetration than a pinhole that irradiates the same detector area
    corecore